Figure 68: Inside View Oft1100Showing Square Fan Assembly - Tekelec 1100 Hardware Manual

Application server
Hide thumbs Also See for 1100:
Table of Contents

Advertisement

Hardware Manual
show me: To view a video (with sound) that shows some steps of the following
procedure,
to read all the steps in the following procedure. For more information about how to
view this video, see
1. Ensure that the following have been done:
a) An RMA has been obtained (see
about the part number to be supplied, see
15. A spare part is available
2. Prepare theT1100 AS chassis for access to the FRU using one of the following procedures:
WARNING: Always wear an ESD wrist strap grounded to the bench or frame
when working on electronic components.
a)
How to SlideT1100 AS Chassis Out from Frame
b)
How to Remove T1100 AS Chassis from a Frame
the fan assembly is replaced while the chassis remains powered)
3. To replace the square fan assembly, first open the front fascia by unscrewing the knurled screws
on either side of the chassis.
Next, unlatch or use key to unlock the latch of the front fascia. Once unlocked, gently swing
open the front fascia from the top of the chassis. The square fan is on the left side of the chassis.
There are two fans inside the square fan assembly; however, the fans are replaced as a unit.
See

Figure 68: Inside view ofT1100showing square fan assembly

location.
CAUTION: Be sure you do not unplug the cable from the printed circuit board
behind the front fascia while opening the front fascia. Removing this cable from
its connections will cause the server to shut down.
Figure 68: Inside view ofT1100showing square fan assembly
910-2969-001 Revision K, June 2009
click
here. For personnel safety and to protect equipment and data, be sure
Programs Needed to View Linked Documents
Hardware Repair and Return
WARNING: TheT1100 AS chassis performance requires all three fan assemblies
(the two rectangular fan assemblies and the square fan assembly) be installed
and operational for optimum performance. The procedure in this section can
be done while the chassis remains powered. TheT1100 AS chassis can operate
with one fan assembly for brief periods. Perform ALL of this procedure without
delay. If the replacement fan assembly is not available, DO NOT begin this
procedure.
on page 11); for information
Fan Assembly Part Number Information
on page 106
on page 108 (do not use this procedure when
on page 117 for square fan assembly
Field Replaceable Units
on page 4.
on page
117