How To Remove T1100 As Chassis From A Frame - Tekelec 1100 Hardware Manual

Application server
Hide thumbs Also See for 1100:
Table of Contents

Advertisement

Field Replaceable Units
PCI cards
WARNING: Always wear an ESD wrist strap grounded to the bench or frame when
working on electronic components.
1. From the front of the frame, simultaneously press the round release buttons and slowly push
the chassis into the frame while observing the cables to avoid binding or stretching.
Note: When the chassis stops moving, the front of the T1100 AS should be slightly recessed
to allow clearance behind the frame door when closed.
2. Adjust the chassis retention brackets on the front of the T1100 AS chassis to contact the frame
adapter brackets when the chassis is positioned correctly in the frame.
3. Secure the chassis with one # 12-24 screw in the chassis retention brackets on each side.
4. This procedure is complete.

How to Remove T1100 AS Chassis from a Frame

It may be necessary to remove a T1100 AS chassis from its frame for either of the following reasons:
To move the chassis to a workbench where one or more of the following FRUs can be replaced
(be sure that a replacement FRU is on hand):
Fan assemblies
Hard disk drive assemblies
Removable media disk drives assembly
PCI cards
Note: Alternatively, these FRUs can be replaced by sliding the T1100 AS chassis partway out
of the frame, using
To remove and replace a failed T1100 AS chassis.
Note: If the hard disk drives and PCI cards in the failed chassis do not need to be replaced,
they can be removed from the failed T1100 AS chassis and placed in the replacement chassis.
Moving the disk drives in this way allows data to be preserved.
Use the following procedure to remove a T1100 AS chassis from the frame.
1. Turn OFF the power switch on the front to the Chassis.
WARNING: This procedure CANNOT be performed while the T1100 AS chassis
is powered on. Never power OFF a T1100 AS chassis until the application software
and platform operating system (OS) are shut down. If possible, use the procedures
in the application manual for a "soft shutdown." If the application interface is not
operating or is not accessible, a hard shutdown (turning OFF the breakers) is
sometimes required. Contact the Customer Care Center before doing a hard
shutdown.
108
How to SlideT1100 AS Chassis Out from Frame
Hardware Manual
on page 106.
910-2969-001 Revision K, June 2009