3 SPECIFICATIONS AND FUNCTIONS

Common functions

Parameter initialization function

Execution data backup function

External I/O signal logic switching function

External I/O signal monitor function

4: For the QD75P /QD75D , this function is available in GX Developer (SW6D5C-GPPW-E or later).
For the QD75P N/QD75D N, external I/O signals cannot be monitored on GX Developer. Use the system monitor of GX Works2.
Common functions
The outline of the functions executed as necessary are described below.
(Refer to PART 2 for details on each function.)
This function returns the "parameters" stored in the QD75
buffer memory and flash ROM to the default values.
The following two methods can be used.
1) Method using sequence program
2) Method using GX Configurator-QP
This functions stores the "setting data", currently being
executed, into the flash ROM.
1) Method using sequence program
2) Method using GX Configurator-QP
This function switches I/O signal logic according to externally
connected devices.
This function enables the use of the system that does not use b
(N.C.)-contact signals, such as Drive unit READY or
Upper/lower limit signal, by setting parameters to positive logic.
This function monitors the external I/O signal monitor
information in the module's detailed information which can be
displayed on the system monitor of GX Developer*4.
Details
3 - 13
MELSEC-Q
Reference
section
13.2
13.3
13.4
13.5