Fig. 5-14: Properly bent
leads.
Fig. 5-16: Soldered and ready to
trim.
Fig. 5-17: Identifying the 18ga wire.
Strip the gray insulation off the four wires. You can discard the single bare wire and the thin
Rostock MAX v2 Assembly Guide
Lay the resistor down on the bottom of the Onyx as shown
and solder into place and trim off the excess leads.
Fig. 5-15: Ready for soldering!
Now grab the 18ga, four conductor wire included in the
wiring pack and cut a section 17" long from it.
The 18ga wire is easy to identify – it's got "18 AWG"
printed in a repeating pattern all along the outer jacket.
71
Need help?
Do you have a question about the Rostock MAX v2 and is the answer not in the manual?
Questions and answers