Status: Interrogator Menu

The Status: Interrogator menu (Figure 3-16) enables the collection of advanced-level status information that
can assist in the diagnostics of projector components. Interrogator can be run in 2 modes and enables the
collection of log files only (Basic Mode) or log files plus registered batch files (Enhanced Mode). These files
are stored to the location specified on your PC. For Interrogator to successfully retrieve these diagnostic files,
the projector must remain in its FAILED state (with incorrectly displayed image on screen). NOTE: Operator
and Operator-Advanced users need to enter a password to access this menu.
NOTES: 1)
during a show as this could cause image
disruption. 2) There is no way of stopping
Interrogator once a request to run it is
applied. Interrogator is also accessible
through a separate login and password
(different from the service login). Contact
Christie technical support for assistance
and password.3) Always run Interrogator
first before power cycling the projector,
otherwise important diagnostic files will
be unusable. 4) It can take 5-10 minutes
for Interrogator to complete its function.

3.5.5 Alarm Window

In addition to the status indicator on the main toolbar of any web
user interface window, a full-screen red alarm window appears if
an alarm condition is encountered (Figure 3-17). This window
displays a description of the alarm condition. Press Acknowledge
to disable the alarm. The current condition remains until it is fixed,
but will not trigger another alarm window. If an interlock failure
occurs, power no longer reaches the lamp and the
the screen is disabled.
3-26
Never run Interrogator
Figure 3-16 Status: Interrogator Menu
button on
LAMP
Figure 3-17 Alarm Window