Lan Operation Mode [Function] - IDK msd-804fd User Manual

Presentation switcher
Hide thumbs Also See for msd-804fd:
Table of Contents

Advertisement

7.11.4 LAN operation mode [FUNCTION]

Set the LAN operation mode consisting of "RECEIVER" mode that controls the MSD externally and
"TRANSMITTER" mode that controls external devices from the MSD.
If you select "TRANSMITTER" mode, you need to set the IP address of the device and the port number to be
connected. The MSD can establish up to eight connections and the operation mode can be set separately.
If HDBaseT output option is mounted, peripheral devices can be controlled via LAN of the twisted pair cable
receiver (HDC series) for each output. The operation mode of HDBaseT output is fixed at "TRANSMITTER".
Item
Controlling the MSD externally or controlling
*1*2
FUNCTION
external devices from MSD.
IP address of target device
*3
IP
Whether you use PJLink (class1) for projector
*3
PJLink
control or not.
Port number for "TRANSMITTER" mode.
(Set the port number for "RECEIVER" mode
*3 *4
in "7.11.5".)
PORT
Password for authentication at PJLink protocol
connection (up to 32 characters).
*3 *5
PASSWORD
Not necessary if you do not perform the
authentication with password.
Mode
RECEIVER mode
TRANSMITTER mode
*2
Operation mode of OUT1B to OUT4B is fixed at "TRANSMITTER".
*3
If selecting "RECEIVER" for operation mode, you do not need to set the item.
*4
If selecting "ON" for PJLink protocol, the target port number is fixed at "4352".
*5
If selecting "OFF" for PJLink protocol, you do not need to set the item.
*6
Connections that are set to "RECEIVER" cannot be used for controlling external devices.
*7
Connections that are set to "TRANSMITTER" cannot be used for controlling the MSD externally.
[Table 7.9] Setting items of LAN operation mode
Description
*1
[Table 7.10] LAN operation mode
External control
Can be used
*7
Cannot be used
RECEIVER [Default]
TRANSMITTER
4 bytes between 0 to 255
[Default] 192.168.001.198
OFF : PJLink is not used. [Default]
ON : PJLink is used.
1 to 65535 [Default]: 1100
Make sure the port number is correct,
because reserved port number that is
only for specific purpose can also be
selected technically.
30 to 39, 41 to 5A, and 61 to 7A
(alphanumeric character) of ASCII
codes.
Final character: 20 (space) [Default]
Controlling external devices using "7.12"
*6
Cannot be used
Can be used
141
MSD-804FD User's Guide
Range

Advertisement

Table of Contents
loading

Table of Contents