6 How to Program the Low Harmonic Drive

6.4.13 15-** FC Information

Par.
Parameter description
No. #
15-0* Operating Data
15-00
Operating Hours
15-01
Running Hours
15-02
kWh Counter
15-03
Power-ups
15-04
Over Temps
15-05
Over Volts
15-06
Reset kWh Counter
15-07
Reset Running Hours Counter
15-08
Number of Starts
15-1* Data Log Settings
15-10
Logging Source
15-11
Logging Interval
15-12
Trigger Event
15-13
Logging Mode
15-14
Samples Before Trigger
15-2* Historic Log
15-20
Historic Log: Event
15-21
Historic Log: Value
6
15-22
Historic Log: Time
15-23
Historic Log: Date and Time
15-3* Alarm Log
15-30
Alarm Log: Error Code
15-31
Alarm Log: Value
15-32
Alarm Log: Time
15-33
Alarm Log: Date and Time
15-4* Drive Identification
15-40
FC Type
15-41
Power Section
15-42
Voltage
15-43
Software Version
15-44
Ordered Typecode String
15-45
Actual Typecode String
15-46
Adj Freq Dr Ordering No.
15-47
Power Card Ordering No.
15-48
LCP ID Num.
15-49
SW ID Control Card
15-50
SW ID Power Card
15-51
Adj Freq Dr Serial No.
15-53
Power Card Serial Number
15-6* Option Ident
15-60
Option Mounted
15-61
Option SW Version
15-62
Option Ordering No
15-63
Option Serial No
15-70
Option in Slot A
15-71
Slot A Option SW Version
15-72
Option in Slot B
15-73
Slot B Option SW Version
15-74
Option in Slot C0
15-75
Slot C0 Option SW Version
15-76
Option in Slot C1
15-77
Slot C1 Option SW Version
15-9* Parameter Info
15-92
Defined Parameters
15-93
Modified Parameters
15-98
Drive Identification
15-99
Parameter Metadata
6-58
Default value
4 set-up
(SR = Size related)
0 h
All set-ups
0 h
All set-ups
0 kWh
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
[0] Do not reset
All set-ups
[0] Do not reset
All set-ups
0 N/A
All set-ups
0
2 set-ups
ExpressionLimit
2 set-ups
[0] FALSE
1 set-up
[0] Log always
2 set-ups
50 N/A
2 set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 ms
All set-ups
ExpressionLimit
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 s
All set-ups
ExpressionLimit
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
0 N/A
All set-ups
®
MG.20.T1.22 - VLT
is a registered Danfoss trademark
VLT AQUA Low Harmonic Drive Instruction
Change during
Conver-
operation
sion index
FALSE
74
FALSE
74
FALSE
75
FALSE
0
FALSE
0
FALSE
0
TRUE
-
TRUE
-
FALSE
0
TRUE
-
TRUE
-3
TRUE
-
TRUE
-
TRUE
0
FALSE
0
FALSE
0
FALSE
-3
FALSE
0
TimeOfDay
FALSE
0
FALSE
0
FALSE
0
FALSE
0
TimeOfDay
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
FALSE
0
Manual
Type
Uint32
Uint32
Uint32
Uint32
Uint16
Uint16
Uint8
Uint8
Uint32
Uint16
TimD
Uint8
Uint8
Uint8
Uint8
Uint32
Uint32
Uint8
Int16
Uint32
VisStr[6]
VisStr[20]
VisStr[20]
VisStr[5]
VisStr[40]
VisStr[40]
VisStr[8]
VisStr[8]
VisStr[20]
VisStr[20]
VisStr[20]
VisStr[10]
VisStr[19]
VisStr[30]
VisStr[20]
VisStr[8]
VisStr[18]
VisStr[30]
VisStr[20]
VisStr[30]
VisStr[20]
VisStr[30]
VisStr[20]
VisStr[30]
VisStr[20]
Uint16
Uint16
VisStr[40]
Uint16