GAL GALaxy eHydro Manual page 95

Elevator controller
Table of Contents

Advertisement

Section 5 – LCD Interface
GALaxy eHydro Elevator Controller
5.2.9.2
Power-Up Mode
When the Main CPU powers up, it runs a power-up routine that verifies the checksum of the controller
program in local flash memory and then verifies that the job configuration file is on the SD Card. If all is
okay, the power-up routine jumps to the controller program. If the power up does not pass verifications,
program control stays in the power-up routine and the elevator is not allowed to run. To enter power-
mode (run the power-up routine), cycle the power while pressing the ENTER and MODE buttons on the
LCD Display Interface and then release the button when the display indicates to do so. Alternately, this
mode can also be entered by placing the car on inspection and selecting the Run Power Up Mode sub-
menu item located in the Software Utilities menu.
Figure 5-29:
5-31