Table 7-7: Group Options
Field Variable
Min
ATT Pref Time
0
CB Button Loc
0
CB Car 2
0
CB IR Penalty
0
CB Rcl anycar
0
CB Req IndCar
0
CB Sel IR Car
0
CB SRiser Car
0
Max
Initial
Units
60
0
Sec
2
0
-
Number
0
Car
Cars
60
10
sec
1
0
-
1
0
-
1
0
-
Number
0
Car
Cars
Section 7 – Main CPU Adjustable Variables
Description
Attendant ETA Preference Time. When set to
nonzero, the car not on attendant service has this
time added to its ETA time. This causes the attendant
car to be given a preference for the hall call.
Code Blue Location.
0 = CB on CB,
1 = CB on HCB,
2 = CB on IR
Code Blue Car #2. When a Code Blue call is initiated,
this will be the car to be sent to respond in the event
that first 'Code Blue Car' is not available, see
variables 'Code Blue Car' and 'CB Rcll Any Car' for
more options.
IR Car Code Blue Penalty Time. It is used to calculate
and give preference to cars in fully automatic
operation
Code Blue Recall Any Call.
0= Disable
1 = Enables dispatcher to recall any car If Code Blue
Cars 1 and 2 are not available.
If you want to select any car as your primary option,
make Code Blue Car and Code Blue Car #2 equal to
zero and enable this setting.
Code Blue Request Independent Car. Code blue
request for car on independent operation. Set to 1 in
dispatcher in all cars so the car could be requested
(flash EML) if the car is in independent mode.
Code Blue Over IR Car
Code Blue Second Riser Car Select.