Example of data stored on the SD Card for the standard or long-term fault log:
8 Inspection Input Flt 11:54:21 2/06/2016 Position = 1 Occurrences = 1 srv=001, prc=002, drf=000,
rdf=000, dpr=000, dir=000, emp=000, med=000 cbl=000, equ=000, fir=000, rfi=000, hsf=000, stf=000,
cal=000, esp=000 nst=000, rlv=000, ste=001, dfs=000, st0=000, ins=01h, nds=000, dev=00h pf1=00h,
pf2=00h, dv2=00h, io0=55h, io1=01h, io2=03h, io3=ffh, io4=b0h io5=c8h, io6=15h, io7=33h, io8=f0h,
io9=21h, ioA=f1h, ioB=7fh, ioC=ffh ioD=ffh, ioE=f5h, ioF=01h, ioG=4dh, ioH=ffh, ioI=00h, ioJ=00h,
ioK=00h
ioL=00h, ioM=00h, ioN=00h, ioO=05h, ioP=16h, ioQ=00h ioR=00h, ioS=09h, ioT=16h statusf=00000040h,
statusf2=00000000h statusf3=00000000h, statusf4=00000000h
DPP Count =
8025, Floor Count =
8025, SD Count =
0
Enc Vel =
0, Enc Dir = 0
Flt Bits 1 = 0h, Flt Bits 2 = 0h, Flt Bits 3 = 0h, Flt Bits 4 = 0h
SS Status=0000h, PWR Status=0000h, Run Status=30805ff8h
NTS Poscnt =
7895, NTS Vel =
0
NTS Cmd1 = 0h, NTS Cmd2 = 10h, NTS Stat1 = 0h, NTS Stat2 = 80h
NTS DoorZone = 0h, NTS Limits = 0h
Nudg Flags=00h, Door Req=08h, Call Flags=00h
Chk Run=1bh, Chk Start=00h, Chk Level=00h, Chk Door=28h
Front SD=0000h, Rear SD=0000h, Motion Tmr=00001
PAL Status=00h, Inspect Svc=000
Percent Load= 0
6-99