GAL GALaxy eHydro Manual page 54

Elevator controller
Table of Contents

Advertisement

GALaxy eHydro Elevator Controller
Table 4-1: Main CPU Inputs & Outputs
Name
DT-1 or DTc
DZ
DZ-1 or DZc
DZA or DZAc
DZO or DZcO
ED
EE
EER
EMP
EPS
EPT
EQ
EXT
FAN
FB
FBNB
FF
FFS
FL
FS
FS2
FS2C
FS2H
FST
FSTi
FSTP
GBP
GLB
GOV
GS
GS-1
GSPI1-3
GSPO1-3
GTS
HB
HBE
HSS
HWLRN
HWS
HWS2
HWSET
Description
Down Terminal Slowdown Output from Main CPU position reference
Door Zone Input from Safety PAL (And of NTS and Main CPU)
Door Zone Output from Main CPU position reference
Door Zone Output from Main CPU position reference
Door Zone Output LED from Main CPU
Extended Door Time Input
Electric Eye Input
Electric Eye Rear Input
Emergency Power Input
Emergency Power Select Input
Emergency Power Transfer Input
Earthquake Sensor Input
Car Top Exit Switch Input
Cab Fan Output
Fire Buzzer Output
Fire Buzzer/Nudging Buzzer Output
Full Field Pilot Output
Fire Fighters Stop Switch Input
Fire Phase I Light Output
Fire Phase I On Hall Switch Input
Fire Switch Phase II On Input
Fire Switch Phase II Call Cancel Input
Fire Switch Phase II Hold Input
Fire Stop Switch Override Output
Fire Stop Switch Override Input
Fire Stop Switch Override Output
Gate Switch Bypass Input.
Gate or Lock Bypass Open
Governor Switch Input
Car Gate Switch Input
Gate Switch Secondary Input.
Group Spare Input 1 – 3
Group Spare Output 1 – 3
Rope Gripper Trip Switch Input.
Handicap Buzzer Output
Handicap Buzzer Enable Input
Hatch Safety String Input
Hoistway Learn
Hoistway Smoke Sensor Input
Hoistway Smoke Sensor 2 Input
COP Hoistway Setup Mode Jumper Input
Section 4 - Troubleshooting