GAL GALaxy eHydro Manual page 62

Elevator controller
Table of Contents

Advertisement

GALaxy eHydro Elevator Controller
A description of each trace setup menu is show below:
Stop Trace – Stops the trace recording.
Start Trace – Starts the trace recording.
Trace Time Interval – Modify the time interval from 10 to 20, 30 or 40 msec. Extends the trace
time from 5 seconds to 10, 15 or 20 seconds respectively.
Trace Trigger Arm – Arm the trace for a condition after power up. The arm condition has to be
met before the trigger condition is checked. The Arm conditions are show below:
o Always Armed
o Power Up Reset
o Initial At Floor
o Motion Start
o Initial Stop
o Relevel Start
o Front Door Open Start
Trace Trigger Window – Time window for logic events to be considered valid. When the trigger
condition is set for more than one condition and a trigger condition occurs momentarily, this is
the duration of time that the momentary condition is considered valid. A value of 35 should
work fine.
Setup Trace Trigger – The logic condition for the trace trigger to occur. There is an "AND"
trigger variable and an "OR" trigger variable. When a trigger condition is selected, the user
must set it in the "AND" or "OR" trigger variable. A trigger condition cannot be set in both
trigger variables. The trigger occurs when all the "AND" conditions are met or any of the "OR"
conditions are met. In addition, the trigger ARM must also be active. Trigger conditions can be
set from the following:
o Fault Change
o Fault Match
o Service Change
o Service Match
o Procedure Change
o Procedure Match
o Run Status Change
o Run Status Match
o Slowdown Change
o Slowdown Match
o Rear Slowdown Change
o Rear Slowdown Match
o Status Change
o Status Match
o Status 2 Change
o Status 2 Match
Section 4 - Troubleshooting
o Front Door Dwell
Start o Front Door
Close Start o Rear
Door Open Start
o Rear Door Dwell
Start o Rear Door
Close Start
o Inspection Start
o Safety String Start
o Fault Bits 0 Change
o Fault Bits 0 Match
o Fault Bits 1 Change
o Fault Bits 1 Match
o Fault Bits 2 Change
o Fault Bits 2 Match
o Fault Bits 3 Change
o Fault Bits 3 Match
o NTS Status 1 Change
o NTS Status 2 Change
o NTS Command 1 Change o
NTS Command 2 Change o
NTS Door Zone Change
o NTS Limit Change
o Status 3 Change
o Status 4 Change
4-16