GAL GALaxy eHydro Manual page 194

Elevator controller
Table of Contents

Advertisement

GALaxy eHydro Elevator Controller
Table 7-3: Car Options
Field Variable
Min
Arrival Lant
0
Behnd CC Canc
0
Cab Lant Ctrl
0
ClGate NoPref
0
COP/Remote
0
CC
COP/RM Dis
0
DCB Canc Dwll
0
Max
Initial
Units
1
0
-
1
0
-
2
0
-
1
0
-
7
0
-
14
0
-
1
0
-
Section 7 – Main CPU Adjustable Variables
Arrival Lantern.
1 = Activate lant/gong without onward call
Behind Car Call Cancel. When enabled the elevator
will not latch any car calls in the opposite direction of
travel.
Cab Lantern Control. The default is for the cab
lanterns to go off when the door is fully open. This
allows the cab lanterns to go off earlier.
+1 = Ring cab lanterns as soon as door starts to open
+2 = Ring the cab lanterns when the door reaches
DPM point.
Close Gate (Swing Door) When No Onward
Preference. The gate on a swing door normally stays
open until a call is placed. This bit causes the gate to
close while the car is sitting at the floor.
COP/Remote Car Call Select.
0 = Both COP and Remote Car Call Station used to
enter calls.
1 = Separate: COP only or Remote CC only used to
enter car calls.
+2 = C-R: Car calls entered on the COP sets the
acknowledgment light on the Remote station.
+4 = R-C: Car calls entered on the Remote station sets
the acknowledgment light on the COP.
COP/Remote Disable.
+1 = Up Direction Disable COP,
+2 = Down Direction Disable COP,
+4 = Up Direction Disable Remote Panel,
+8 = Down Direction Disable Remote Panel
Door Close Button Cancel Dwell Time. When this
parameter is set to 1 we do not allow DCB to cancel
the door dwell time. This basically disables DCB to
shorten door dwell time.
7-9