GALaxy eHydro Elevator Controller
Table 6-0: Main CPU Faults
Faults
CTCAN
Device Fault
CTCAN
Device Reset
DL Failed On Fault
DL20 Phone Test
Failed
DLB & DLB-1
Opposite
DLM & DLM-
1 Opposite
DLT & DLT-1Opposite
Description
Device on the Car Top
CAN Port has a Fault.
On the LCD Interface,
this fault is display as
an abbreviated device
name and device fault.
Please see the device
faults for further
information.
Device on the Car Top
CAN Port has reset.
On the LCD Interface,
this fault is display as
an abbreviated device
name and device fault.
Please see the device
faults for further
information.
DL Failed On Fault.
The DL leveling input
did not turn off during
a run. The DL input is
set from a count from
the APS selector.
Phone Test from DL20
phone monitoring
device indicated a
failure
Input failure on one of
the Door Lock Bottom
(DLB) inputs.
Input failure on one of
the Door Lock Middle
(DLM) inputs.
Input failure on one of
the Door Lock Top
(DLT) inputs.
Section 6 – Main CPU Faults & Detailed Faults
Possible Cause/Suggested Fix
• Look at the details of the fault. The device name and the
error code that caused the fault are listed.
• Look up the fault code for the device for debugging
information.
• Look at the details of the fault. The device name and the
error code that caused the fault are listed.
• The device requested an initialization packet from the
main CPU. Typically, this occurs during power up or from a
power cycle of the individual device.
• Ignore the error if the controller power has been cycled.
Otherwise, check the device communications and power
connections.
• The APS selector did not change count during a run. Check
for faults related to the APS selector. Verify that the APS
selector counts change while the car is running.
• The elevator did not leave the floor on a run attempt.
Verify that the elevator can run from the landing. Check the
fault log for another fault that could prevent the car from
running.
• Refer to the manufacturers troubleshooting guide for the
DL20.
• Faulty DLB or DLB-1 input (replace input chip).
• Faulty DLM or DLM-1 input (replace input chip).
• Faulty DLT or DLT-1 input (replace input chip).