Table 7-8: Color Lights
Field Variable
Min
HCDn OnBright
0
HCU Off Brght
0
HCU Off Color
0
HCU On Bright
0
Max
Initial
100
100
100
20
15
15
100
0
Section 7 – Main CPU Adjustable Variables
Hall Call Light On Brightness for LED hHll Call
Buttons. Used only with GAL serial hall button
fixtures.
Hall Call Output Off Brightness for LED (higher
number is brighter)
Hall Call Button Up Light Off Color.
Based on RGB intensity parameters.
0 Based on Parameters
1 Red
2 Orange
3 Yellow
4 Chartreuse
5 Green
6 Aquamarine
7 Cyan
8 Azure
9 Blue
10 Violet
11 Magenta
12 Rose
13 Rose White
14 Warm White
15 Cool White
Hall Call Output Up On Brightness for LED (higher
number is brighter)