Table 6-3: Faults from the COP Board Devices on the CTCAN Serial Port
Fault
No LED Board
Stuck Button
Description
Car Call LED board missing
Car Call Board stuck button
Section 6 – Main CPU Faults & Detailed Faults
Possible Cause/Suggested Fix
• Faulty LED signal from RGB Board. Look at detailed
car faults log to determine device. 'dev' gives you
address for global CAN device, 'dv2' gives you local
CAN device and 'pf1' the number for the IO location
within the local board.
• Faulty LED signal from RGB Board. Look at detailed
car faults log to determine device. 'dev' gives you
address for global CAN device, 'dv2' gives you local
CAN device and 'pf1' the number for the IO location
within the local board.