GAL GALaxy eHydro Manual page 159

Elevator controller
Table of Contents

Advertisement

GALaxy eHydro Elevator Controller
Table 6-2: Faults from the Hall Call Driver Board Devices on the GRCAN Serial Port
Fault
Description
Up LED Open
HCB led open up
Up LED Short
HCB led short up
Up LED Short
HCB led short up
Section 6 – Main CPU Faults & Detailed Faults
Possible Cause/Suggested Fix
• Make Sure there is a GALX-1056AN attached to the proper
connector (Up LED always attached to CN5, Down LED attached to
CN5 if only down call at that station (like the top floor), otherwise
attached via ribbon at CN6.
• Replace GALX-1056AN for the associated up or down call.
• Make Sure there is a GALX-1056AN attached to the proper
connector (Up LED always attached to CN5, Down LED attached to
CN5 if only down call at that station (like the top floor), otherwise
attached via ribbon at CN6.
• Replace GALX-1056AN for the associated up or down call.
• Make Sure there is a GALX-1056AN attached to the proper
connector (Up LED always attached to CN5, Down LED attached to
CN5 if only down call at that station (like the top floor), otherwise
attached via ribbon at CN6.
• Replace GALX-1056AN for the associated up or down call.
6-95