GAL GALaxy eHydro Manual page 174

Elevator controller
Table of Contents

Advertisement

GALaxy eHydro Elevator Controller
CkLevS: Check Level Start Status State
0 = No Level Op
1 = CPU UN Off
2 = MC Failed Off
3 = SPD Fail Off
4 = RUNU Fail On
5 = RUNU Fail Off
6 = CPU Out On Up
7 = NTS UN Off
8 = SU Failed Off
9 = SUF Failed On
CkDrS: Check Door Status State
0 = No Door Op
1 = Fire Door
2 = Med Em Svc
3 = EAQ Door Open
4 = EMP Wait DC
5 = EMP Home DO
6 = EMP Home DC
7 = EMP RCL Door
8 = Stall Op Door
9 = Hot Oil Door
10 = MedEm RCL @Fl
11 = MedEm RCL
12 = MedEm Wait Sw
13 = MedEm Svc Op
14 = Hospital Svc
15 = CB Ovr FS RCL
16 = CB Ovr FS Svc
17 = F1 Recall @FL
18 = F1 Recall
19 = F1 Complete
20 = F1 or F2
Section 6 – Main CPU Faults & Detailed Faults
10 = Level Up
11 = CPU DN Off
12 = RUND Fail On
13 = RUND Fail Off
14 = CPU Out On Dn
15 = NTS DN Off
16 = SD Failed Off
17 = SDF Failed On
18 = Level Down
21 = At Floor Chk
22 = Front DPM
23 = Rear DPM
24 = CodeBlue RCL
25 = CodeBlue Svc
26 = VIP Recall
27 = VIP Service
28 = Independent
29 = Overload
30 = Elevator Off
31 = Prison Svc
32 = Push Button
33 = Attendant
34 = Extended Door
35 = Sabbath
36 = RTL Door Cl
37 = Lobby Recall
38 = Car Elev Off
39 = HW Elev Off
40 = Automatic
6-110

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents