GAL GALaxy eHydro Manual page 192

Elevator controller
Table of Contents

Advertisement

GALaxy eHydro Elevator Controller
Table 7-2: Car Timers
Field Variable
Min
OSER SSopen T
0
Pas Chime Tim
0.2
RC Pick Delay
0
RCDrop Fail T
0.5
Relev Dly Tim
0
Reset Time
0
RTL Dwell Tim
1
Run Cycle Tim
0
Sabb Buzz Dly
1
Max
Initial
Units
900
60
sec
2
0.5
sec
7
0
sec
5.5
0.5
sec
2
1
sec
10
5
sec
60
8
sec
300
0
hours
10
5
sec
Section 7 – Main CPU Adjustable Variables
Description
Out of Service Safety String Open Time. Time to
control the OSERL output. Used with OSERL control
option 1 for ' SS open' set to 4.
Floor Passing Chime Time. Length of time the floor
passing chime will sound when a floor is passed.
Retiring Cam Pick Delay. The amount of delay time
for the retiring cam to pick once the doors are closed.
Retiring Cam Drop Fail Time. Retiring cam drop fail
safe delay for manual doors. Delay time when car
arrives to the floor before it drops the output.
Relevel Delay Time. The amount of delay time before
the car will re-level. This would be used for jobs that
have excessive rope stretch.
Reset Time. Delay time in the reset mode before
allowing the car to run.
Return To Lobby Dwell Time. If Return To Lobby is
set to cycle doors at the lobby, use this timer to
control how long they will dwell before closing in
return to lobby mode.
Run Cycle Time. Used to initiate a run when the
elevator has been sitting idle for a period of time.
Used for jobs that have high friction bearing
machines.
Sabbath Door Buzzer Timer (prior to doors closing).
Jobs where the light curtain is disabled in Sabbath
operation require a buzzer prior to the door closing
sequence. This timer warns people the light curtains
are about to be enabled (output name: SABUZ)
7-7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents