GAL GALaxy eHydro Manual page 220

Elevator controller
Table of Contents

Advertisement

GALaxy eHydro Elevator Controller
Table 7-7: Group Options
Field Variable
Min
EP ATTcar 1st
0
EP Man Sel En
0
EP Rcl Out En
0
EP Recall Dly
0
EP Recovr Tim
1
GrpCC Ovrride
0
Max
Initial
Units
1
0
-
3
1
-
1
0
-
3200
30
Sec
60
20
Sec
1
0
-
Section 7 – Main CPU Adjustable Variables
Description
Emergency Power Attendant Car First. Select and
Prioritize the attendant car for running on emergency
power service. It won't be recalled. After recall is
complete for the group, It recovers and goes back in
service
Emergency Power Manual Select Enable.
0 = The recall sequence is aborted and any moving
car will stop at the next floor to allow the selected car
to run.
+1 = Car is selected to run when the currently
selected car completes its recall.
+2 = Makes the selected car wait for all the cars to
recall before being selected to run.
Emergency cars finished Recalling Output Enable.
It enables an output in the hall call board for
Emergency Power Complete (EPCOM). This setting is
only read in power up so after changing this setting
you need to reboot the controller.
Emergency Power Recall Delay Time. Time delay
before the group starts the emergency power recall
sequence.
Emergency Power Recover Time. When elevators
are in Emergency Power recall, this is the time that
the dispatcher will wait for each car to recover to a
floor. If the car is in the middle of a blind shaft, you
need to calculate the time each car may take to get
to a floor in emergency power recovery speed.
Group Car Call Override. Normally visitor access
allows the car call security to be overridden
momentarily from a push button in an owners
apartment. With this parameter set to 1, the security
override works directly from a key switch input.
7-35

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents