GALaxy eHydro Elevator Controller
Table 7-2: Car Timers
Field Variable
Min
Sabbath Dwell
1
Sec Dis Time
0
Shrt Dwll Tim
0
Shutdn Alrm T
5
Stall Time
20
VIP Door Time
1
Y Delta Time
1
Table 7-3: Car Options
Field Variable
Min
2nd Risr Lant
0
Max
Initial
Units
60
10
sec
3200
0
sec
60
1
sec
1500
120
sec
3200
60
sec
3200
20
sec
5
1.5
sec
Max
Initial
Units
1
0
-
Section 7 – Main CPU Adjustable Variables
Description
Sabbath Door Dwell Time. Car will wait this amount
of time on every floor for Sabbath operation except at
the lobby where it will follow the handicap dwell door
time (separate timer).
Security Disable Time. This timer is used with a
security disable input button at the lobby. When the
button is pressed, the car call security is disabled for
the time value set from this parameter.
Short Door Dwell Time. Door open dwell time when
the doors re-open on a door open button, electric
eye, safety edge or door hold button.
Shutdown Alarm Timer.
Stall Time. Maximum time a run is requested but the
car is not moving.
VIP Door Time. The amount of time the car will park
at the VIP recall floor prior to going to automatic
service.
Y-Delta Time. Transfer time to change motor from Y
start to Delta run. Timer also used for DEL or MCX
turn on time with controllers without y-delta starters.
Second Riser Lantern. Turn on cab lantern only when
IR call answered. If this parameter is set cab lanterns
will only turn on when answering second riser calls.