GALaxy eHydro Elevator Controller
Table 7-7: Group Options
Field Variable
Min
Code Blue Car
0
Em Power Cars
1
Bottom
Em Pwr Floor
Floor
Emer Dispatch
0
EmPwr Op
0
Outp
EmPwr Pk
0
Outp
Max
Initial
Units
Number
0
Car
Cars
Number
1
Car
Cars
Top
1
Floor
Floor
7
0
-
3
0
-
2
0
-
Section 7 – Main CPU Adjustable Variables
Description
Code Blue Car. When a code blue call is initiated, this
will be the first car to be sent to respond. If car is not
available, see variables 'Code Blue Car#2' and 'CB Rcll
Any Car' for more options.
Number of Emergency Power Cars. that can run at
the same time on the emergency power source.
Emergency Power Recall Floor.
Emergency Dispatch. This parameter is applied to
both the car that is selected as the dispatcher and
also the non-dispatcher cars.
Dispatcher Car = If set to 1 and hall call power lost,
the dispatcher car will set down hall calls above the
lobby and up hall call at and below the lobby.
Non-Dispatcher Car = If set to a 1, and
communications is lost to the dispatcher car, the car
will dispatch itself to down hall calls above the lobby
and up hall calls below the lobby.
The front hall call and rear hall call bits settings are
only used for the dispatcher car and when set, if
communication is lost to a particular hall call board,
hall calls are set for the affected floors.
Emergency Power Operation LED. This parameter
controls the group outputs for emergency power
status for each car.
0 = Outputs are on for cars that are operational.
1 = Outputs on for cars on normal power.
2 = Outputs on for car on emergency power.
3 = Outputs on for cars that are being recalled.
Emergency Power Park LED. This parameter controls
the group outputs for emergency power parked
status for each car.
0 = Cars are parked on emergency power.
1 = Cars are parked or selected to run.