GAL GALaxy eHydro Manual page 30

Elevator controller
Table of Contents

Advertisement

GALaxy eHydro Elevator Controller
Step 6: Wire the APS Selector Camera according to the connection diagrams.
The APS selector should be wired according to the job specific wiring schematic and
connection diagrams. See Figure 2-11.
Figure 2-13: Wire APS Camera According to Wiring Schematic and Connection Diagram
Prior to performing "Step 7" below, the eHydro controller must be installed, and the APS selector
must be properly wired according to the wiring schematics. See Section 3 of this manual.
Step 7: Perform a fine adjustment of the APS camera.
Make the fine adjustment of the camera using the LED array on the top of the APS camera. See
Figure 2-14.
Adjust the camera so only the green LED in the middle of the 4 red arrows is on. See Figure
2-16.
Temporarily obstruct the field of view of the APS camera for 5 seconds, and then remove the
obstruction. Two red alignment spotlights should appear on the encoded tape. These spotlights
represent the center of the field of view of each APS camera. Adjust the camera so the
spotlights are in the center of the encoded tape. See Figure 2-15.
Level the APS camera with a leveling device. The APS camera must be parallel and square to
the encoded tape. See Figure 2-17.
The PWR and STAT LED's indicate the status of the APS. See Table 2-1.
Section 2 –Installation