GAL GALaxy eHydro Manual page 199

Elevator controller
Table of Contents

Advertisement

GALaxy eHydro Elevator Controller
Table 7-4: Service Options
Field Variable
Min
Acc Door Cls
0
Bottom
Access Bot Fl
Floor
Bottom
Access Top Fl
Floor
Att Buz ctrl
0
Att CC frm HC
0
CCPBS Grp Sec
0
CCS on Sabb
0
CEOF Cntrl 2
0
Max
Initial
Units
1
0
-
Top
1
floor
Floor
Top
2
floor
Floor
1
1
-
1
0
-
1
0
-
1
0
-
15
0
-
Section 7 – Main CPU Adjustable Variables
Access Door Close. When on access operation the car
runs with the Door Lock and GS open. By turning this
parameter on, the car needs to have the gate switch
signal ON in order to run. It should be used on
hoistways where the car door will physically hit
something if moved on access operation
Access Bottom Floor. Floor for bottom access
Access Top Floor. Floor for bottom access
Attendant Buzzer Control.
0 = Hall Calls only
1 = Hall Calls and Car Calls
Attendant Car Call from Hall Call.
1 = When the car is on Attendant service the
respective car call will register when a hall call is
registered.
CCPBS On Group Car Call Security. This variable
enables Car Call Push Button Security with group car
call lockout switches. The configuration file (CONS)
setting for security type and car call push button
security must also be set.
Car Call Security on Sabbath. When this parameter is
enabled, sabbath car calls will not latch on floors that
have been secured using car call lockouts security
Car Elevator Off Options 2:
+1= Keep doors Closed (do not cycle on reversal),
+2 = Do not blink Elevator Off Light,
+4 = Elevator Off Auto Reset With Timer,
+8 = Enable Elevator Off Light to indicate the car
finished recall of elevator off mode
7-14

Hide quick links:

Advertisement

Table of Contents
loading