Table 5-9: CkDrS: Check Door Status State
0 = No Door Op
1 = Fire Door
2 = Med Em Svc
3 = EAQ Door Open
4 = EMP Wait DC
5 = EMP Home DO
6 = EMP Home DC
7 = EMP RCL Door
8 = Stall Op Door
9 = Hot Oil Door
10 = MedEm RCL @Fl
11 = MedEm RCL
12 = MedEm Wait Sw
13 = MedEm Svc Op
14 = Hospital Svc
15 = CB Ovr FS RCL
16 = CB Ovr FS Svc
17 = F1 Recall @FL
18 = F1 Recall
19 = F1 Complete
20 = F1 or F2
Table 5-10: Front SD (FSd): Front Slowdown Flags
Bit 0: (UC) Up Hall Call Slowdown
Bit 1: (DC) Down Hall Call Slowdown
Bit 2: (CC) Car Call Slowdown
Bit 3:
Bit 4: (UD) Up Call Door Open Request
Bit 5: (DD) Down Call Door Open Request
Bit 6: (CD) Car Call Door Open Request
Bit 7:
Table 5-11: Rear SD (RSd): Rear Slowdown Flags
Bit 0: (UC) Up Hall Call Slowdown
Bit 1: (DC) Down Hall Call Slowdown
Bit 2: (CC) Car Call Slowdown
Bit 3:
Bit 4: (UD) Up Call Door Open Request
Bit 5: (DD) Down Call Door Open Request
Bit 6: (CD) Car Call Door Open Request
Bit 7:
21 = At Floor Chk
22 = Front DPM
23 = Rear DPM
24 = CodeBlue RCL
25 = CodeBlue Svc
26 = VIP Recall
27 = VIP Service
28 = Independent
29 = Overload
30 = Elevator Off
31 = Prison Svc
32 = Push Button
33 = Attendant
34 = Extended Door
35 = Sabbath
36 = RTL Door Cl
37 = Lobby Recall
38 = Car Elev Off
39 = HW Elev Off
40 = Automatic
Bit 8: (IU) IR Up Hall Call Slowdown
Bit 9: (ID) IR Down Hall Call Slowdown
Bit 10:
Bit 11:
Bit 12:
Bit 13:
Bit 14:
Bit 15:
Bit 8: (IU) IR Up Hall Call Slowdown
Bit 9: (ID) IR Down Hall Call Slowdown
Bit 10:
Bit 11:
Bit 12:
Bit 13:
Bit 14:
Bit 15: