3.3 Adjustment Procedures

Remove all temporary connections.
Verify that all safety circuits and safety devices are installed and functioning properly.
Verify that all car door electric contacts or car door interlocks are functioning properly.
Verify that all hoistway door interlocks are functioning properly.
Verify that all hoistway doors and car doors are closed.
Verify that the elevator is safe to operate and that all individuals are clear from moving
equipment.

3.3.1 Set Toggle Switches

Set all toggle switches on the 1121 Main I/O board as follows:
DOOR LOCKS - "OFF"
IND - "IND"
AUTO DOOR - "OFF"
STOP - "RUN"

3.3.2 Ready the Car to Run on Inspection

The car should be ready to run on inspection if all is wired correctly. Select the "Elevator Status" on the
Main CPU LCD interface. The display should show INS on the car service area of the first main display.
Pressing the DOWN button to the next display will show the type of inspection the car is on as in the list
below:
Machine Room
Car Top
Access
In-Car
Car Top Lock Bypass
Car Top Gate Bypass
Car Top G & L Bypass
COB HW Setup Jumper
To run the car from the machine room, Machine Room inspection should be displayed.
The "inspection string" consists of contacts from the inspection switches and the gate and lock bypass
switches in series as shown in Figure 3-3. One and only one of the five inspection inputs should be on
for the car to run..
NOTE: Any one of the following conditions will generate an inspection error.
More than one inspection input is on
No inspection input is on
Gate or Lock Bypass switch in the BYPASS position when the car is not on car top inspection