GALaxy eHydro Elevator Controller
Table 7-4: Service Options
Field Variable
Min
Emer Dispatch
0
HC Ack Buz
0
HEOF Cntrl 2
0
HEOF Cntrl 3
0
HEOF Control
0
Max
Initial
Units
7
0
-
1
0
-
15
0
-
1
0
-
7
0
-
Section 7 – Main CPU Adjustable Variables
Emergency Dispatch. This parameter is applied to
both the car that is selected as the dispatcher and
also the non-dispatcher cars.
Dispatcher Car = If set to 1 and hall call power lost,
the dispatcher car will set down hall calls above the
lobby and up hall call at and below the lobby.
Non-Dispatcher Cars = If set to a 1, and
communications is lost to the dispatcher car, the car
will dispatch itself to down hall calls above the lobby
and up hall calls below the lobby.
The front hall call and rear hall call bits settings are
only used for the dispatcher car and when set, if
communication is lost to a particular hall call board,
hall calls are set for the affected floors.
HC Acknowledge Attendant Buzzer. Buzz once (for
one sec) every time a call comes in.
0 = Disable
1 = Enable
Hall Elevator Off Options 2.
+1= Keep doors Closed (do not cycle)
+2 = Do not blink HEOFL,
+4 = Auto Reset when input off and timer expires.
+8 = Use HEOFL to indicate car finished recall.
Hall Elevator Off Options 3.
+1 = Only activate if doors are closed. See other Hall
Elevator Off Options as well.
Hall Elevator Off Control.
+1 = Recall car when key switch activated.
+2 = Keep door open at the shutdown floor.
+4 = Allow the cab light and fan to time-out even
though the door is open but the car is shut down.
7-16