GALaxy eHydro Elevator Controller
Table 7-9: System Options
Field Variable
Min
Hall Lan Baud
0
Low Door Volt
0
Low Line Volt
0
Password
0
Pword Tim-out
0
Safe Test Day
1
SafeTest Year
2000
SafeTst Month
1
Max
Initial
6
0
600
198
600
198
9999
0
3200
300
31
0
2999
0
12
0
Section 7 – Main CPU Adjustable Variables
Hall Lantern COM Baud Rate.
0 = 2400,
1 = 4800
2 = 9600
3 = 19.2K
4 = 38.4K
5 = 57.6K
6 = 115.2K bits per second.
Low Door Voltage. Settings for Line Voltage Monitor
Board. It sets the value of voltage for 'Door Low
Voltage Fault' to be triggered.
Low Line Voltage. Settings for Line Voltage Monitor
Board. It sets the value of voltage for a 'Low Line
Voltage Fault' to be triggered.
Password Code to modify and adjust field variables
Password Time-out. The amount of inactive time for
the LCD to lock out the field variables.
Safety Test Day.
Safety Test Year.
Safety Test Month.
7-56