GAL GALaxy eHydro Manual page 197

Elevator controller
Table of Contents

Advertisement

GALaxy eHydro Elevator Controller
Table 7-3: Car Options
Field Variable
Min
NCU Lant Ctrl
0
NCU Pref Ctrl
0
NoHC Dor
0
Reop
Non-Simul Dor
0
Nudg No Calls
0
Nudge Dis Ctl
0
Max
Initial
Units
3
0
-
1
0
-
3
0
-
2
0
-
1
0
-
7
0
-
Section 7 – Main CPU Adjustable Variables
Next Up Direction Lantern Control.
+1 = Turn off hall lantern after next up time.
+2 = Turn off cab lantern after next up time.
Next Up Preference Control. When set allows
direction preference to change before the door starts
to close after the next up door time.
No Hall Call Button Door Reopen. When set do not
reopen the door from an at floor hall call.
Non-Simultaneous Doors.
0 = Both front and rear doors will open at the same
time if there is a demand at both the front and rear
openings.
1 = The front doors will open first before the rear
doors open if there is a demand to open.
2 = The rear doors will open first before the front
doors open if there is a demand to open.
Nudge with No Calls. If set the doors will close on
nudging even if the elevator has no onward calls.
Nudging Disable Control.
+1 = Do not turn on the NUD output when doors are
in nudging close mode, basically you are disabling
nudging output.
+2 = When doors are in nudging close mode and SE
input is ON, keep doors open and also keep FB/NB
output latched.
+4 = Sound the nudging buzzer but do not close the
doors on nudging.
7-12