GALaxy eHydro Elevator Controller
Table 7-10: NTS Processor Adjustable Variables
Field Variables
Min
Can Baud Rate
0
Debug Mode
0
Number Valid
2
Fl
Top Speed
0
UT Limit Dist
0
DT Limit Dist
0
Table 7-11: Velocity Slowdown Table
FPM
50
75
100
150
200
Max
Initial
1
0
7
0
Top
2
Floor
1600
200
50
0
50
0
UN/DN *
UT/DT *
5"
2" above top
9"
floor and
12"
below bottom
21"
floor
30"
Section 7 – Main CPU Adjustable Variables
CAN Baud Rate. Set to zero and do not change.
Special jobs uitilize a different baud rate for CAN Bus.
All devices need to be reconfigured for new rate. CAN
Baud Rate,
0 = 115.2K,
1 = 57.6K
Debug Mode
Number of Valid Floors.
Top Speed or Contract Speed of the car.
Up Terminal Limit Distance
Down Terminal Limit Distance
TSD
4"
7"
10"
17"
22"
TLH
4" above top
floor
7-57