Table 7-2: Car Timers
Field Variable
Min
Hall Lant Dly
0
Handicap Dwll
1
HC Dwell
1
HEOF AutoRstT
0
IND Rcl2Lby T
10
Lant Off Time
0
Lant On Time
0
Max
Initial
Units
15
0
sec
120
25
sec
60
4
sec
3200
0
sec
60
20
sec
2
0.2
sec
2
0.7
sec
Section 7 – Main CPU Adjustable Variables
Description
Hall Lantern Delay Time. By default, when set to
zero, hall lanterns go off as soon as the car starts to
slow down to arrive at a floor. When set to a nonzero
value, this will be used as a timer for the hall lantern
to go off prior to arriving at the floor. For example, if
set to three seconds, hall lanterns will turn on
approximately three seconds before the car arrives to
the floor regardless of the speed of the car. We
recommend to set this parameter for high speed cars.
Handicap Dwell. Extended door time from pressing
the ED button in the car.
Hall Call Dwell. Door open dwell time when
answering a hall call or both a hall and car call.
HEOF Auto Reset Time. When the hall elevator off
function is activated from the HEOF input being
turned on, the car will be taken out of service until
the input is turned off. Once the input is off, the car
will stay out of service until the auto reset timer times
out.
Independent Recall to Lobby Timer. Recall delay for
car in Independent when 'IND Rcl to Lby ' is set.
Lantern Off Time. Used for double stroke gongs. The
lantern off time is the delay time after the lantern
first turns on until it turns off.
Lantern On Time. Used for double stroke gongs. The
lantern will turn on, turn off and then turn on again.
The Lantern on time is the delay time from when the
lantern first turns on until it turns on the second time.
7-5