GAL GALaxy eHydro Manual page 158

Elevator controller
Table of Contents

Advertisement

GALaxy eHydro Elevator Controller
Table 6-2: Faults from the Hall Call Driver Board Devices on the GRCAN Serial Port
Fault
Description
Can't internally read
information from
Tx->above fl
Transmitter
to device above
Can't internally read
information from
Tx->below fl
Transmitter to device
below
Can't internally read
information from
Tx->below fl
Transmitter to device
below
Up FET Open
HCB fet open up
Up FET Open
HCB fet open up
Up FET Short
HCB fet short up
Up FET Short
HCB fet short up
HCB Up input
Up Input Ovld
overload
Up LED Open
HCB led open up
Section 6 – Main CPU Faults & Detailed Faults
Possible Cause/Suggested Fix
• Cable connecting two devices could be flip- flopped (i.e., gray
wire goes from pin 1 on one end to pin 8 on the other end).
Disconnect cable, and if fault changes to Rx Fault, the problem is
the cable.
• Transmitter is bad, Replace the Device
• Cable connecting two devices could be flip- flopped (i.e., gray
wire goes from pin 1 on one end to pin 8 on the other end).
Disconnect cable, and if fault changes to Rx Fault, the problem is
the cable.
• Transmitter is bad, Replace the Device
• Cable connecting two devices could be flip- flopped (i.e., gray
wire goes from pin 1 on one end to pin 8 on the other end).
Disconnect cable, and if fault changes to Rx Fault, the problem is
the cable.
• Transmitter is bad, Replace the Device
• Replace GALX-1054AN
• Replace GALX-1054AN
• Replace GALX-1054AN
• Replace GALX-1054AN
• Controller detected overload in the input from the LED board at
the station. To identify fault device refer to Detailed Fault Log 'dev'
and 'dv2' will provide address for Serial Driver address and Station
where the fault was generated.
• Make Sure there is a GALX-1056AN attached to the proper
connector (Up LED always attached to CN5, Down LED attached to
CN5 if only down call at that station (like the top floor), otherwise
attached via ribbon at CN6.
• Replace GALX-1056AN for the associated up or down call.
6-94

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents