GALaxy eHydro Elevator Controller
Table 7-9: System Options
Field Variable
Min
COM2 Port Sel
0
COM3 Baud
0
Cpu Timg Outp
0
Display T-out
0
ExclusionFLT1
0
Max
Initial
7
0
3
2
7
0
3200
0
Max
0
Faults
Section 7 – Main CPU Adjustable Variables
Com 2 Port Select. Selects the operation of COM
2 port.
0 = Comm Diag,
1 = Comm Debug,
2 = Galcom,
3 = DL20,
4 = Galcom Wireless,
5 = Galcom Ethernet,
6 = Galcom Wireless Flow Control,
7 = Galcom Ethernet Flow Control
COM3 Baud Rate.
0 = 2400
1 = 4800
2 = 9600
3 = 19200
CPU Timing Output. The CPU has three test point
pins that outputs timing signals depending upon the
setting of this parameter. These are 5 Volt signals that
can be monitored by an oscilloscope.
0 = Z6 LED 1 second pulse
1 = Inctime
2 = GrpIO
4 = 10 msec.
Display Time-out. Turn off the LCD Display after this
timer times out. This function is disabled when set to
zero.
Exclusion fault 1. Set to fault code number. This
prevents faults from being recorded in the fault log. It
should only be set for nuisance and noncritical faults.
Controller stills goes through all the logic for each
fault code except, a call is not recorded in the fault log
7-54