GAL GALaxy eHydro Manual page 203

Elevator controller
Table of Contents

Advertisement

GALaxy eHydro Elevator Controller
Table 7-4: Service Options
Field Variable
Min
Manual Dir En
0
No Psg RunCnt
0
PI Serv Msg 1
0
PI Serv Msg 2
0
PI Serv Msg 3
0
Retrn To Lbby
0
Max
Initial
Units
4
0
-
10
0
count
Max
0
Svc #
Service
Max
0
Svc #
Service
Max
0
Svc #
Service
7
0
-
Section 7 – Main CPU Adjustable Variables
Attendant Manual Direction Enable.
1 = Works in conjunction with the ATTUP and ATTDN
to determine direction of travel.
2 = Reads the ATTUP input and use it as a START
button.
4 = Will not allow car calls to be registered until the
door is fully closed.
No Passenger Run Count. When set to a number
other than zero, the car call antinuisance feature is
activated. This count is the number of times the car
will run from a car call without detecting that a
passenger has broken the detector edge. Once the
count is reached, all remaining car calls will be
cancelled.
PI Service Message 1. When the car service matches
this number, user message 1 is sent to the PI display.
This will correspond to user PI display message 17.
PI Service Message 2. When the car service matches
this number, user message 2 is sent to the PI display.
This will correspond to user PI display message 18
Service Message 3 Display. Used for Custom
messages. Need to be programmed by CE electronics
and GAL for special messages
Return to Lobby Option.
+1 = Cycle door at lobby,
+2 = Cancel car calls when activated,
+4 = Cycle door on reversal.
7-18