GAL GALaxy eHydro Manual page 188

Elevator controller
Table of Contents

Advertisement

GALaxy eHydro Elevator Controller
Table 7-2: Car Timers
Field Variable
Min
AdvDoor
0
EnTim
Att Buz Delay
0
AttBuz On Tim
1
AttBuzOff Tim
0
AutoSwg
0
DODly
CB Door Time
1
CC Dwell
1
Chime on CC T
0.1
Max
Initial
Units
240
0
sec
900
60
sec
30
5
sec
30
0
sec
10
1
sec
3200
60
sec
60
2
sec
2
0.2
sec
Section 7 – Main CPU Adjustable Variables
Description
Advanced Door Enable Time. Door open advance
enable time to open the opposite door when
operating with non-simultaneous doors. If there is a
request for both doors, instead of waiting for the first
open door to close completely before opening the
second door, the second door starts to open after the
advance door enable time while the first door is
closing.
Attendant Buzzer Delay. Buzzer sounds if a hall call is
entered and the car has not started moving within
this delay time. This function is disabled when set to
zero.
Attendant Buzzer On Time. Cycle on timer to turn
attendant buzzer on and off once attendant delay
time function has been met (See ATTBuz Delay).
Attendant Buzzer Off Time. Cycle off time to turn
attendant buzzer on and off once attendant delay
time function has been met (See ATT Buz Delay).
Buzzer will stay on continuously if this timer set to
zero.
Auto Swing Door Open Delay. Delay time to enable
the auto swing door open output.
Code Blue Door Time. Door time for Code Blue
operation once elevator is at the emergency floor
before EMS is energized
Car Call Dwell. Door open dwell time when answering
a car call only.
Chime on Car Call Time. Handicap buzzer on CC.
Length of beep time.
7-3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents