GALaxy eHydro Elevator Controller
Table 6-2: Faults from the Hall Call Driver Board Devices on the GRCAN Serial Port
Fault
Description
HCB Down input
Dn Input Ovld
overload
Dn LED Open
HCB led open down
Dn LED Open
HCB led open down
Dn LED Short
HCB led short down
Dn LED Short
HCB led short down
HCB fet open blue
FET Open BluD
down
FET Open BluU
HCB fet open blue up
HCB fet open green
FET Open GrnD
down
Section 6 – Main CPU Faults & Detailed Faults
Possible Cause/Suggested Fix
• Controller detected overload in the input from the LED board at
the station. To identify fault device refer to Detailed Fault Log 'dev'
and 'dv2' will provide address for Serial Driver address and Station
where the fault was generated.
• Make Sure there is a GALX-1056AN attached to the proper
connector (Up LED always attached to CN5, Down LED attached to
CN5 if only down call at that station (like the top floor), otherwise
attached via ribbon at CN6.
• Replace GALX-1056AN for the associated up or down call.
• Make Sure there is a GALX-1056AN attached to the proper
connector (Up LED always attached to CN5, Down LED attached to
CN5 if only down call at that station (like the top floor), otherwise
attached via ribbon at CN6.
• Replace GALX-1056AN for the associated up or down call.
• Make Sure there is a GALX-1056AN attached to the proper
connector (Up LED always attached to CN5, Down LED attached to
CN5 if only down call at that station (like the top floor), otherwise
attached via ribbon at CN6.
• Replace GALX-1056AN for the associated up or down call.
• Make Sure there is a GALX-1056AN attached to the proper
connector (Up LED always attached to CN5, Down LED attached to
CN5 if only down call at that station (like the top floor), otherwise
attached via ribbon at CN6.
• Replace GALX-1056AN for the associated up or down call.
• Replace the GALX-1093AN board – dev / dev 2 can pinpoint which
1093 is at fault.
• Replace the GALX-1093AN board – dev / dev 2 can pinpoint which
1093 is at fault.
• Replace the GALX-1093AN board – dev / dev 2 can pinpoint which
1093 is at fault.
6-88