To make floor position count changes at individual floors select the "Hoistway Tables" menu and then
the "Floor & SD Count" screen. See Figure 3-8. Hit UP or DOWN to access the desired floor and then
press ENTER to go into edit mode. Change the floor count to the desired location and then run the car
away from the floor and then back again.
If the car stops in the desired level position, place the car on inspection and learn the floor from the
procedure in section 2.7.2. The floor position can also be relearned in the Machine Room from the LCD
Interface, "Elevator Setup"->" Learn Hoistway". Follow the prompt from the LCD display and make sure
not to mistakenly clear the hoistway table if floors have already been learned, i.e., select NO when
prompted to "Clear HW Table<U/D>? No". When the new value for the floor is learned, the floor count
value is also updated in the NTS Processor. This will make sure that the door zone positions for both
the Main CPU and the NTS Processor turn on at the same time.

3.4.4 Verify Proper Operation of All Safety Circuits and Signal Devices

Remove all temporary connections.
Verify that all safety circuits and safety devices are installed and functioning properly.
Verify that all car door electric contacts or car door interlocks are functioning properly.
Verify that all hoistway door interlocks are functioning properly.
Verify that all signal devices are functioning properly.

3.4.5 Perform Required Tests

Complete all required inspections and tests before placing the elevator in service.
Figure 3-7: Floor and SD Count Display
Section 3 – GALaxy Startup and Adjustment
3-10