GAL GALaxy eHydro Manual page 36

Elevator controller
Table of Contents

Advertisement

GALaxy eHydro Elevator Controller
To record the floor position, press the buttons on the car operating panel in the following
sequence.
o
Press the 2
o
Press the 1
o
Press the 2
o
Press the 1
o
Press the Door close button
The car call light for floors 1 and 2 will illuminate momentarily and then turn off.
After the two car call lights turn off, press the following button on the car operating panel.
o
Press the car call button for the floor where the car is currently located.
This car call light will flash on and off for approximately 5 seconds and then remain off.
This indicates that the floor position was recorded successfully. If the car call light does
not flash, but remains illuminated, the floor was not recorded successfully. If the floor
position was not recorded successfully, verify that the APS SEL adjustable variables are
set properly.
st
The 1
floor car call is the car call for the bottom terminal landing. The 2
the car call for the landing that is one floor above bottom terminal landing. The actual
floor markings for these floors may not be "1" and "2".
Repeat this process until all valid floors have been recorded.
Set the car door bypass switch to the OFF position.
The hoistway learn is now complete.
Proceed to section 3.3.3.
nd
floor car call button
st
floor car call button
nd
floor car call button
st
floor car call button
Section 2 –Installation
nd
floor car call is
2-18

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents