Audible Alarm

Testing
Electrical System: Component Testing
g288610
1.
Front power center
The audible alarm sounds to notify the operator when a machine problem exists.
Electrical current for the alarm is provided as an output from the slave controller.
The audible alarm is located in the front power center behind the operator seat
(Figure
264).
1. Make sure key switch is OFF. Remove key from key switch.
2. Remove power center cover from operator platform to access audible alarm
and disconnect machine wire harness from alarm.
Make sure to observe polarity on the alarm terminals when testing.
Damage to the alarm may result from an improper connection.
1
g288611
1.
Top view
2.
Bottom view
3. Correctly connect 12VDC power to the terminals as shown
alarm should sound. Replace the alarm if necessary.
4. Reconnect machine wire harness to alarm.
5. Install and secure power center cover.
2
1
Figure 264
2.
Audible alarm
IMPORTANT
3
Figure 265
3.
Positive (+) terminal
4.
Negative (−) terminal
Page 6–122