Brake Release Manifold Installation
Groundsmaster
®
5900 & 5910
16227SL Rev B
(Figure
1. If fittings were removed from manifold, lubricate and place new O−rings onto
fittings. Install fittings into manifold openings using marks made during the
removal process to properly orientate fittings. Tighten hydraulic fittings to
torque value provided
for hydraulic fittings, see
Thread O-Ring Fittings) (page
2. Position brake release manifold in the frame and secure with two (2) cap
screws, flat washers and flange nuts.
3. Remove caps and plugs from fittings and tubes. Using labels placed
during removal, properly connect hydraulic tubes to manifold (see
Hydraulic Hoses and Tubes (O-Ring Face Seal) (page
4. Make sure hydraulic tank is full. Add correct oil if necessary (see Operator's
Manual).
5. Check hydraulic system for leaks, and check brake operation before returning
the machine to service.