Toro Groundsmaster 5900 Series Service Manual page 215

Hide thumbs Also See for Groundsmaster 5900 Series:
Table of Contents

Advertisement

Brake Release Manifold Installation
Groundsmaster
®
5900 & 5910
16227SL Rev B
(Figure
1. If fittings were removed from manifold, lubricate and place new O−rings onto
fittings. Install fittings into manifold openings using marks made during the
removal process to properly orientate fittings. Tighten hydraulic fittings to
torque value provided
for hydraulic fittings, see
Thread O-Ring Fittings) (page
2. Position brake release manifold in the frame and secure with two (2) cap
screws, flat washers and flange nuts.
3. Remove caps and plugs from fittings and tubes. Using labels placed
during removal, properly connect hydraulic tubes to manifold (see
Hydraulic Hoses and Tubes (O-Ring Face Seal) (page
4. Make sure hydraulic tank is full. Add correct oil if necessary (see Operator's
Manual).
5. Check hydraulic system for leaks, and check brake operation before returning
the machine to service.
101)
(Figure
102). For information on tightening procedures
Installing the Hydraulic Fittings (SAE Straight
5–9).
Page 5–115
Installing
5–7)).
Hydraulic System: Service and Repairs

Advertisement

Table of Contents
loading

This manual is also suitable for:

Groundsmaster 5910 series

Table of Contents