Hydraulic Oil Cooler
2
3
4
5
6
7
8
9
g288226
1.
Cooling fan assembly
2.
Cap screw (4)
3.
Flat washer (4)
Hydraulic Oil Cooler Removal
Hydraulic System: Service and Repairs
4.
Cap screw (4)
5.
Flat washer (4)
6.
Isolator Mount (4)
(Figure
133)
The oil cooler may be hot. To avoid possible burns, allow the engine
and hydraulic systems to cool before working on the oil cooler.
1. Park machine on a level surface, lower cutting decks fully, disengage PTO
and stop engine. Remove key from the key switch.
2. Raise hood to gain access to oil cooler.
3. Read the
General Precautions for Removing and Installing Hydraulic System
Components (page
1
8
Figure 134
CAUTION
5–73).
Page 5–160
2
3
4
5
6
7.
Oil Cooler
8.
Hydraulic straight fitting (2)
9.
Flange nut (4)
Groundsmaster
16227SL Rev B
®
5900 & 5910