Toro Groundsmaster 5900 Series Service Manual page 402

Hide thumbs Also See for Groundsmaster 5900 Series:
Table of Contents

Advertisement

24 Volt System Battery Specifications
Battery Removal
Electrical System: Service and Repairs
Quantity: 2
BCI Group Size UI
340 CCA at −17.8 ºC (0 ºF)
Reserve Capacity of 38 minutes at 26.7 ºC (80 ºF)
Dimensions
Length
Width
Height (including terminals)
Weight
Electrolyte Specific Gravity
Fully charged: 1.265 corrected to 26.7 ºC (80 ºF)
Discharged: less than 1.240
2
g288669
1.
Rear bumper
2.
Flange head screw (remove 3 per side)
3
1
Figure 279
3.
Flange head screw (loosen 1 per side)
Page 6–140
198 mm (7.8 in)
132 mm (5.2 in)
183 mm (7.2 in)
8.8 Kg (19.5 lb)
Groundsmaster
®
5900 & 5910
16227SL Rev B

Advertisement

Table of Contents
loading

This manual is also suitable for:

Groundsmaster 5910 series

Table of Contents