Toro Groundsmaster 5900 Series Service Manual page 494

Hide thumbs Also See for Groundsmaster 5900 Series:
Table of Contents

Advertisement

Installation
(Figure
Operator Cab : Service and Repairs
341) (continued)
6. Remove caps that were placed on hoses and fittings during the removal
process. Using labels placed during removal, properly secure hoses to
compressor.
7. Connect compressor electrical connector to machine wire harness.
8. Have a certified air conditioning service technician evacuate the air
conditioning system completely, properly recharge the system with R134a
refrigerant and then leak test the system. A/C system capacity is 3.43 lb
of R134a refrigerant.
9. Lower and secure hood.
Page 9–8
Groundsmaster
®
5900 & 5910
16227SL Rev B

Advertisement

Table of Contents
loading

This manual is also suitable for:

Groundsmaster 5910 series

Table of Contents