Piston (Traction) Pump Installation
Groundsmaster
®
5900 & 5910
16227SL Rev B
(Figure
8. Remove plugs and caps from disconnected hydraulic hoses and fittings of
the pump assembly. Install hydraulic lines to correct location on gear and
piston pumps (see
O-Ring Fittings) (page 5–9)
(O-Ring Face Seal) (page
N·m (30 to 45 in−lb).
9. Using labels placed during pump removal, connect wire harness connectors
to the two (2) solenoid coils on left side of piston pump
10. Lower machine to ground.
Refer to
Traction Circuit Component Failure (page 5–5)
information regarding the importance of removing contamination
from the traction circuit.
11. Install new hydraulic filter and fill hydraulic reservoir with correct oil.
12. Prime hydraulic pumps (see
13. Properly fill hydraulic system (see
14. Stop engine and check for hydraulic oil leaks. Check hydraulic reservoir oil
level and adjust if necessary.
15. Install side shrouds if previously removed and close hood (see
Lower Shrouds (page
87) (continued)
Installing the Hydraulic Fittings (SAE Straight Thread
and
Installing Hydraulic Hoses and Tubes
5–7)). Tighten suction hose clamp from 3 to 5
IMPORTANT
Priming Hydraulic Pumps (page
Charge Hydraulic System (page
7–47)).
Page 5–97
(Figure
88).
for
5–76)).
5–79)).
Hood and
Hydraulic System: Service and Repairs