DIAGNOSTICS SCREENS
INPUT/OUTPUT
Electrical System: InfoCenter Display
g288373
1.
Button 1
2.
Button 2
3.
Button 3
The Diagnostic screen
provides access to the following screens:
•
Input / Output
•
Fault Viewer
Access the diagnostics screens by pressing buttons 1 or 2 to highlight the
desired screen and button 4 to select the highlighted screen.
Return to the previous screen by pressing button 5.
The input/output screens display the current state of the various Toro Electronic
Controller (TEC) inputs, qualifiers and outputs necessary to allow a machine
functions to occur. The input/output screens should be used to troubleshoot
machine operation issues, and check that necessary components and circuit
wiring are functioning correctly (see Troubleshooting chapter). Scroll through
the input/output screens by pressing buttons 1 or 2.
Each of the following machine functions has its own input/ output screen:
•
Left cutting deck raise and lower
•
Center cutting deck raise and lower
•
Right cutting deck raise and lower
•
Traction control forward and reverse
•
Traction control high/low speed range selection
•
PTO engagement
•
Cruise control
•
Engine starting and running
•
Air filter service indicator