Toro Groundsmaster 5900 Series Service Manual page 286

Hide thumbs Also See for Groundsmaster 5900 Series:
Table of Contents

Advertisement

INPUT/OUTPUT (continued)
Electrical System: InfoCenter Display
To lower the left wing deck, the following inputs and qualifiers are required
(Figure
153):
Operator seat needs to be occupied (SEAT ON).
High/Low traction speed range switch in LO position (HIGH RANGE
REQUEST OFF).
Hydraulic solenoid valve SV should be de−energized (HIGH RANGE OFF).
Left wing deck raise/lower switch pressed to lower (LEFT DECK LOWER ON).
If the proper inputs and qualifiers exist, the following outputs should occur
(Figure
153):
Hydraulic solenoid valve S1 should be energized (MASTER LIFT SOLENOID
ON).
Hydraulic solenoid valve S3 should be energized (LEFT DECK LOWER ON).
Hydraulic solenoid valve S4 should be energized (LEFT DECK FLOAT ON).
g288317
Once the deck is fully lowered, the deck should float and following outputs
should occur
(Figure
154):
Hydraulic solenoid valve S4 should be energized (LEFT DECK FLOAT ON).
Note: If a deck is already fully lowered when the key switch is moved
from OFF to RUN, the deck will not be in float until the deck raise/lower
switch is momentarily pressed to lower.
Figure 154
(Float)
Page 6–24