Inspection
Hydraulic Reservoir Installation
Groundsmaster
®
5900 & 5910
16227SL Rev B
1. Clean hydraulic reservoir and suction strainer with solvent.
2. Inspect reservoir for leaks, cracks or other damage.
(Figure
1. Install reservoir:
A. Position reservoir in frame and install hold down bracket and cap screws.
Install spacer, flat washer and cap screw at front of reservoir.
B. Tighten drain plug (item 21) from 18 to 19 N·m (155 to 171 in−lb).
C. Tighten suction strainer (item 22) from 143 to 155 N·m (105 to 115 ft−lb).
2. Remove caps or plugs placed during removal to prevent contamination.
3. Using tags placed during reservoir removal, properly connect hydraulic hoses
to stand pipes, vent fitting and suction strainer, and secure with hose clamps.
4. If hose guard (item 32) was removed, install guard with split orientated up
and secure with two (2) cable ties.
5. Slide fuel tank to proper location on machine and secure in place (see
System (page
4–17)).
6. Fill reservoir with new hydraulic fluid and check for leaks before returning
machine to service.