Komatsu 830E-AC Shop Manual page 404

Dump truck, serial numbers a30001-a30035
Hide thumbs Also See for 830E-AC:
Table of Contents

Advertisement

EVENT
NUMBER
DESCRIPTION
127/227
INVERTER, PHASE B+
:02
Bup temp short
:03
Bup temp open
:04
Bup temp warm
:05
Bup temp hot
:06
Bup fb not off S
128/228
INVERTER, PHASE B-
:01
alarm BN
:02
Bdn fb not off
:03
phase B modl neg
:04
hold BN
:05
Bdn fb not on
:06
Bdn IGBT not on
:07
IGBT_PS_BN
129/229
INVERTER, PHASE B- (NR)
:02
Bdn temp short
:03
Bdn temp open
:04
Bdn temp warm
:05
Bdn temp hot
:06
Bdn fb not off S
130/230
INVERTER, PHASE B CURR
:01
I sensor ph B
:02
IB zero not ok
:03
IB not ok
:04
I snsr ph B open
:05
I sensr ph B short
132/232
INVERTER, PHASE B VOLTS
:01
V sensor phase B
:02
VB not ok
134/234
INVERTER, PHASE C+/C-
:01
alarm C
:02
PTF C
:04
IGBT_SAT_CP
:05
IGBT_SAT_CN
E2-20
Table 3: DID PANEL FAULT CODES
(Codes Received from Inverter 1 & 2)
EVENT
RESTRICTION
Electrical Propulsion System Components
EVENT
Phase B up thermistor short
Phase B up thermistor open
None
Phase B up thermistor warm
Phase B up thermistor hot
Phase B up not off with enable/DC volts
Phase B negative IGBT did not turn off.
Phase B down feedback is not off.
Phase B negative module failed.
INV1 (INV2) off
Phase B positive and negative IGBTs are on (negative
turn on).
Phase B down feedback is not on.
Phase B negative IGBT did not turn on.
IGBT protective shutoff
Phase B down thermistor short
Phase B down thermistor open
None
Phase B down thermistor warm
Phase B down thermistor hot
Phase B down not off with enable/DC volts
Phase B current sensor failed.
Current IB not zero at startup
INV1 (INV2) off
Phase B current too high
Phase B current sensor open
Phase B current sensor short
INV1 (INV2) off
Phase B voltage sensor failed.
Phase B voltage too high
Phase C IGBT did not turn off.
INV1 (INV2) off
Overcurrent on phase C
IGBT saturated
IGBT saturated
DETECTION
INFORMATION
10/06 E02020

Advertisement

Table of Contents
loading

Table of Contents