Komatsu 830E-AC Shop Manual page 357

Dump truck, serial numbers a30001-a30035
Hide thumbs Also See for 830E-AC:
Table of Contents

Advertisement

7. At the prompt type "dispvhmsinf". Information
similar to the following will be displayed:
>dispvhmsinf
---- MACHINE INFORMATION --------
PRODUCT GROUP: Dumptruck
MACHINE_MODEL: 830AC-
MACHINE_SERIAL:
ENG_MODEL: QSK60
ENG_SERIAL_NO1:
ENG_SERIAL_NO2:
PRG_NO1: 12000100100
PRG_NO2: 782613R290
---- DEVICES ------------------------
PLC NO CONNECTION
PLM23 Disabled
PLM3 CONNECTED
---- Condition --------------------
SMR: 90.0 H
DATE 04-10-25 TIME14:44:24
TIMEZONE: 0.0 H SUMMERTIME 0
----Controller Info -------------------
PartNumber: 0000000000
Serial No.: 000000
Compo Name: KDE1010
SilkyID: VA011740744
>
NOTE: Use the results of step 6 and 7 to confirm that
the correct software is installed in the VHMS
controller.
D13004
VHMS CHECK-OUT & TROUBLESHOOTING
8. The VHMS controller also has two red LED
lights (10 and 11, Figure 13-6). Verify the con-
nection status and repair any problems.
Light (10) PLM III communication
• OFF - no communication with the PLM III
controller.
Troubleshoot
connection.
• ON - communication with the PLM III controller is
good.
Light (11) OrbComm
• OFF - no communication with OrbComm
controller.
Troubleshoot
connection.
• ON - communication with OrbComm controller is
good.
• FLASHING - satellite in view and signal
established, which is good.
and
repair
the
and
repair
the