Komatsu 830E-AC Shop Manual page 396

Dump truck, serial numbers a30001-a30035
Hide thumbs Also See for 830E-AC:
Table of Contents

Advertisement

EVENT
NUMBER
DESCRIPTION
055
FRONT WHEEL TACHS
056
INVERTER SW VERSION
:01
Inverter # 1
:02
Inverter # 2
061
MOTOR OVERSPEED
063
ENGINE LOAD SIGNAL
:01
below minimum
:02
above maximum
:03
:04
:05
065
TEMP INPUT RANGE CHECK
:01
aux pc temp sensor
:02
aux inv temp sensor
:03
afse temp sensor
:04
alternator temp
:05
left stator temp
:06
left rotor temp
:07
right stator temp
:08
right rotor temp
:09
chopper IGBT temp
:10
chopper diode temp
:11
left IGBT module temp
:12
left diode temp
:13
right IGBT module temp
:14
right diode temp
:15
rectifier diode temp
070
LINK CAPACITANCE LEVEL LOW
071
LINK CAPACITANCE LEVEL TOO LOW
072
GROUND FAULT CIRCUIT
074
INV1 COMM FAILED
:01
No communication Inverter #1
:02
Inverter #1 customer option bit
075
INV2 COMM FAILED
:01
No communication Inverter #2
:02
Inverter #2 customer option bit
E2-12
Table 2: DID PANEL FAULT CODES
(Codes Received from PSC)
EVENT
RESTRICTION
Electrical Propulsion System Components
EVENT
SYS Event
Incorrect version of Inverter Software is installed.
SYS Event
SYS Event
Truck is over the motor overspeed limit.
Engine load out of range.
SYS Event
PWM signal failed low.
PWM signal failed high.
PWM signal failed incorrect period.
An analog input is outside the design range of valid
values.
Auxiliary phase controller temperature sensor
Auxiliary inverter temperature sensor
AFSE temperature sensor
Speed limit
Temperature is out of range.
SYS Event
Link capacitance level is low, but OK.
Speed Limit
Link capacitance level is too low.
Speed Limit
Ground fault detection circuit
INV1 Disable
INV2 Disable
DETECTION
INFORMATION
10/06 E02020

Advertisement

Table of Contents
loading

Table of Contents